BSBDY - UCON LUBRICANT LB-650-XY23
- MSDS: BSBDY
- Manufacturer: UNION CARBIDE CORP INDUSTRIAL CHEMICALS DIV
- Product Name: UCON LUBRICANT LB-650-XY23
- National Stock Number: 9150-00D003106
Product Identification
Product ID:UCON LUBRICANT LB-650-XY23
MSDS Date:02/18/1993
FSC:9150
NIIN:00D003106
MSDS Number: BSBDY
Responsible Party
DANBURY, CT 06817-0001
US
Emergency Phone: 304-744-3487
Info Phone: 800-822-4357
Cage: 61637
Contractor
Telephone: 901-775-0100
Cage: 91522
Ingredients
POLYPROPYLENE GLYCOL MONOBUTYL ETHER
CAS: 9003-13-8
RTECS: TR4680000
Fraction By Weight: >95%
PROPRIETARY ADDITIVES
Fraction By Weight: <30%
N-PHENYL-ALPHA-NAPHTHYLAMINE
CAS: 90-30-2
RTECS: QM4500000
Fraction By Weight: <3%
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MFR STATES "NO EVIDENCE OF HARMFUL
EFFECTS FROM AVAILABLE INFORMATION." IN RESPONSE TO ALL CHRONIC AND
ROOM TEMPERATURE ACUTE EXPOSURES. ALSO "CONTAINS ONE OR MORE AMINES
WHICH MAY REACT WITH NITRATES TO FORM NITROSOMINES. SOME
NITROSAMINES ARE CARCINOGENIC IN LAB ANIMALS"
Explanation of Carcinogenicity:THIS PRODUCT CONTAINS NO INGREDIENT AT
0.1% OR GREATER THAT IS LISTED BY IARC, NTP OR OSHA AS A
CARCINOGEN.
Effects of Overexposure:OVER EXPOSURE TO VAPOR GENERATED AT HIGH
TEMPERATURES MAY RESULT IN EYE & RESPIRATORY TRACT IRRITATION,
DIZZINESS, NAUSEA AND INHALATION OF HARMFUL AMOUNTS OF MATERIAL.
Medical Cond Aggravated by Exposure:EXPOSURE TO THIS MATERIAL MAY
DECREASE THE OXYGEN-CARRYING CAPACITY OF THE BLOOD. INDIVIDUALS
W/CARDIOVASCULAR DISEASE OR IMPAIRMENT OF THE RESPIRATORY FUNCTION
MAY BE AT INCREASED RISK.
First Aid
First Aid:SKIN:WASH WITH SOAP & WATER. EYES:FLUSH THOROUGHLY WITH WATER
FOR SEVERAL MINUTES. INGESTED:NO EMERGENCY CARE ANTICIPATED.
INHALED:REMOVE TO FRESH AIR.
Fire Fighting
Flash Point Method:PMCC
Flash Point:300F,149C
Lower Limits:NOT DETERMIN
Upper Limits:NOT DETERMIN
Extinguishing Media:USE FOAM APPLIED BY MANUFACTURERS RECOMMENDED
TECHNIQUES FOR LARGE FIRES. CARBON DIOXIDE, DRY CHEMICAL FOR SMALL
FIRES.
Fire Fighting Procedures:DO NOT DIRECT STREAM OF WATER OR FOAM DIRECTLY
INTO FLAMING POOL. MAY CAUSE FROTHING & INCREASE FIRE INTENSITY.
USE SCBA & PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:DURING FIRE, OXIDES OF NITROGEN MAY BE
PRODUCED.
Accidental Release
Spill Release Procedures:WEAR SUITABLE PROTECTIVE EQUIPMENT. SMALL
SPILLS CAN BE FLUSHED WITH LARGE AMOUNTS OF WATER; LARGER SPILLS
SHOULD BE COLLECTED FOR DISPOSAL.
Neutralizing Agent:NO INFORMATION GIVEN ON MSDS BY MFR.
Handling
Handling and Storage Precautions:AVOID BREATHING VAPOR. KEEP CONTAINER
CLOSED. USE WITH ADEQUATE VENTILATION. DO NOT ADD NITRATES OR OTHER
NITROSATING AGENTS. FOR INDUSTRIAL USE ONLY.
Other Precautions:THIS PRODUCT HAS VERY LOW SOLUBILITY IN WATER. AVOID
DRAINAGE OF LARGE SPILLS TO SEWERS OR TO NATURAL WATERS.
Exposure Controls
Respiratory Protection:NONE REQUIRED FOR USE AT LOW TEMPERATURES.
Ventilation:GENERAL ROOM VENTILATION IS SATISFACTORY FOR USE AT LOW
TEMPERATURES. AT HIGH TEMPS USE LOCAL EXHAUST WHERE VAPORS START
Protective Gloves:POLY VINYL CHLORIDE COATED
Eye Protection:SAFETY GLASSES
Other Protective Equipment:SAFETY SHOWER & EYE BATH
Work Hygienic Practices:MFR: ? HMIS:USE GOOD CHEMICAL HYGIENE
PRACTICE. AVOID UNNECESSARY CONTACT. WASH THOROUGHLY BEFORE EATING
OR DRINKING.
Supplemental Safety and Health
KEY2:KT
Chemical Properties
HCC:V6
NRC/State Lic Num:NONE
Boiling Pt:B.P. Text:>392F,>200C
Melt/Freeze Pt:M.P/F.P Text:<-20F,<-29C
Vapor Pres:NIL
Vapor Density:>50
Spec Gravity:1.0
Evaporation Rate & Reference:NIL
Solubility in Water:NIL
Appearance and Odor:AMBER LIQUID,MILD ODOR.
Percent Volatiles by Volume:NIL
Stability
Stability Indicator/Materials to Avoid:YES
NORMALLY UNREACTIVE. AVOID STRONG BASES AT HIGH TEMPERATURES, STRONG
ACIDS, STRONG OXIDIZERS.
Stability Condition to Avoid:DO NOT MIX WITH NITRATES OR OTHER
NITROSATING AGENTS AS A NITROSAMINE (A CARCINOGEN) MAY BE FORMED.
Hazardous Decomposition Products:OXIDES OF CARBON & NITROGEN.
Disposal
Waste Disposal Methods:INCINERATE IN A FURNACE OR OTHERWISE DISPOSE OF
I/A/W FEDERAL, STATE & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.